thedroidblog.com

  • Home
  • Vsam Repro Return Code 28
  • Contact
  • Privacy
  • Sitemap
Home > Return Code > Vsam Repro Return Code 28

Vsam Repro Return Code 28

Contents

  • Vsam Repro Return Code 28
  • Vsam Error Codes
  • The value indicates the status of that request.

VSAM and QSAM File Status Codes/keys from IBM manual Printout of SQLcodes for DB2, Version 7 SQLcodes SQLCODES for DB2 Version 8 from the IBM manual GC18-7422-0 04/06/05 Abend codes / All Rights Reserved. In most installations, this is not the common practice. But what wonders me is why the job failed when running in production and couldnt able to use the production pools , where as the same completed fine when used thetest http://thedroidblog.com/return-code/vsam-catalog-return-code-is-8-reason-code-is-igg0cleg-42.html

The first group of documents may be available from a local system or via an internet connection, the second group of documents will require an internet connection. This is where XXXXX was able to successfully create a test version of these files. The combinations of possible values and their meanings are shown below with some comments where vendor additions or extensions may occur. We have made a significant effort to ensure the documents and software technologies are correct and accurate.

Vsam Repro Return Code 28

We reserve the right to make changes without notice at any time. The last I/O statement executed for the file, before the execution of a DELETE or REWRITE statement, was not a READ statement. 44 A boundary violation exists. For VSAM, you get 90 CI per CA with 8192 CISIZE. 20% of those are free, so 72 usable CI per cylinder.

  • Current Server or Internet Access The following links may be to the current server or to the Internet.
  • Also, check to see if the path to the file concerned exists (Micro Focus). 14 Relative files only.
  • In this case, the physical size of the new record is allowed to be smaller than that of the record being replaced. 46 A sequential READ operation has been tried on
  • LISTCAT will tell you.I checked , No records were loaded into the VSAM file Nara_513 Posts: 44Joined: Fri Dec 02, 2011 1:11 am Hasthanked: 0 time Beenthanked: 0 time Top

VSAM Open error codes 136(88) Not enough Virtual-Storage Space is available for Work Areas, Control Blocks, or Buffers. 144(90) An uncorrectable I/O error occurred while VSAM was Reading or Writing a The following table lists +---------------+--------------------------------------------------------| | 004 | End of volume - Non-extended addressable. File Status Keys Return Codes for Data Files & VSAM Table of Contents v-16.01.01 - vsmfsk01.htm Introduction File Status Key Overview Primary File Status 00 This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers.

sg1OA30026Your IBM Storage management guys "should" be able to solve this quickly. Vsam Error Codes This is usually caused by a conflict with record-length, key-length, key-position or file organization. Explore The Micro Focus Web Site via Internet Connect for more information about products and services available from Micro Focus. Sandeep. > -----Original Message----- > From: Mohan, Bezawada (B.) [SMTP:[login to unmask email] > Sent: Thursday, January 31, 2002 11:44 AM > To: [login to unmask email] > Subject: Re: vsam

MAXIMUM CONDITION CODE WAS 12 IDC3351I ** VSAM {OPEN|CLOSE|I/O} RETURN CODE IS return-code {RPLFDBWD=nnnnnnnn} Explanation: An error was encountered during virtual storage access method (VSAM) open, close, or action Indicates a boundary violation. Refer to the section for Status-Key-1 being equal to "0" for additional information based on Status-Key-2. 1End of File, attempting to read beyond the end of the file. Alternatively a START or READ operation has been tried on an optional input file that is not present. 24 Relative and indexed files only.

Vsam Error Codes

The documentation and software were developed and tested on systems that are configured for a SimoTime environment based on the hardware, operating systems, user requirements and security requirements. StatusKey-1Description by Group 0Successful Completion or non-terminal condition that may be acceptable to continue processing. Vsam Repro Return Code 28 These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats. Idc3351i This information may be subject to legal professional or other privilege or may otherwise be protected by work product immunity or other legal rules.

SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. http://thedroidblog.com/return-code/eza1735i-std-return-code-10000-error-code-00008.html After all these changes my job worked fine but I have confusion whether I need to change the CONTROLINTERVALSIZE for alternate index also. Is This Answer Correct ? 37 Yes 4 No
Answer / carina Unable to extend dataset Is This Answer Correct ? 7 Yes 2 No
Answer / deepak No c62ap90 Posts: 125Joined: Thu Oct 11, 2012 10:24 pm Hasthanked: 1 time Beenthanked: 6 times Top Re: Unable to copy a flat file to VSAM KSDS file by Nara_513 » Iec070i 209-220

However, if you do check the code for QSAM files, they return a subset of the codes shown below. The rule of thumb I've used for years is 4 bytes + half the key length gives the average compressed key length stored in the index CI. 4 + (12 / They also ranout of ideas regarding this .Can any one suggest whether am missing any thing here in this , which actually solves my problem .Thanks for your time Nara Nara_513 Source Refer to the section for Status-Key-1 being equal to "4" for additional information based on Status-Key-2. 9Implementor Defined, Many vendors take advantage of the x"00' to x'FF' (or 0-255) binary value.

Status-key-2Decimal Status-key-2Hex Description 9000 00 No further information. 9001 01 Insufficient buffer space. In the world of programming there are many ways to solve a problem. AIXKEY=(12,10) .AXS06 - UNABLE TO EXECUTE VSAM WRITE.

The value indicates the status of that request.

Glossary of Terms Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers. Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web You have reached the end of the file. 12 Attempted to open a file that is already open. 13 File not found. Check the ASSIGN(EXTERNAL) directive and possible environment variable setting for the COBOL file name. 9005 05 Illegal device specification. 9006 06 Attempt to write to a file opened for input. 9007

MAXIMUM CONDITION CODE WAS 12 > ******************************** Bottom of Data ************************ > > Cheers > > Mohan Bezawada > > > > > International DB2 Users Group 330 North Wabash, Suite non-SMS DASD.Just curious if any records loaded to your VSAM file? The Recording Mode is Variable or Fixed or not defined the same as when the file was created. 3. http://thedroidblog.com/return-code/bpxf135e-return-code-00000081-reason-code-0594003d.html Explore How to Obtain and Display the File Status after attempting to access a data file or VSAM data set.

Possible causes:Attempting to write beyond the externally defined boundaries of a file.Attempting a sequential WRITE operation has been tried on a relative file, but the number of significant digits in the Thanks Nara Nara_513 Posts: 44Joined: Fri Dec 02, 2011 1:11 am Hasthanked: 0 time Beenthanked: 0 time Top Re: Unable to copy a flat file to VSAM KSDS file by Refer to the section for Status-Key-1 being equal to "9" for additional information based on Status-Key-2. Taking out the overhead, and with 20% free space per CI, there are 6545 bytes of usable space per CI, which allows 14 records per CI. 14 times 72 gives a

Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration. Note:A SimoTime License is required for the items to be made available on a local system or server. CONDITION CODE IS 12 > 0 > 0IDC0002I IDCAMS PROCESSING COMPLETE. Explore the non-Relational Data Connection for more examples of accessing methodologies and coding techniques for Data Files and VSAM Data Sets.

Back to top Anuj DhawanIntermediateJoined: 19 Jul 2007Posts: 298Topics: 7Location: Mumbai,India Posted: Tue Mar 31, 2009 7:01 am Post subject: Hi, This beacomes a site specific topic now - may be A good place to start is The SimoTime Home Page via Internet Connect for access to white papers, program examples and product information. The subfunction information field, if present, contains a decimal problem-determination code (reason code) for use by the IBM Support Center in case further problem diagnosis is necessary. Too many files open simultaneously (Micro Focus). 15 Too many indexed files open (Micro Focus). 16 Too many device files open (Micro Focus). 17 Record error: probably zero length (Micro Focus).

So here my problem is , when i run the same job JCL (which got failed in production) using the personal datasets in spool , the job completed fine . Copyright © 1987-2017SimoTime TechnologiesAll Rights Reserved File Status Key Overview The ANS/85 standard provides for a two-byte File-Status-Key. Robert Sample Global moderator Posts: 3156Joined: Sat Dec 19, 2009 8:32 pmLocation: East Dubuque, Illinois Hasthanked: 1 time Beenthanked: 190 times Top Re: Unable to copy a flat file to

© Copyright 2017 thedroidblog.com. All rights reserved.